Determination of Phthalates in Tear Tapes for Cigarette Packaging Using Ultrasonic Extraction / ASE Method Coupling with GC-MS

LIU Dan, CHENG Juan, FANG Xi-ling, KUANG Shu-ting, WANG Zhi-wei

Packaging Engineering ›› 2013 ›› Issue (19) : 14-17.

Packaging Engineering ›› 2013 ›› Issue (19) : 14-17.

Determination of Phthalates in Tear Tapes for Cigarette Packaging Using Ultrasonic Extraction / ASE Method Coupling with GC-MS

  • LIU Dan1, FANG Xi-ling1, CHENG Juan2, KUANG Shu-ting2, WANG Zhi-wei2
Author information +
History +

Abstract

A GC-MS method for simultaneous detection of 10 kinds of phthalates was developed. DEHP and DIBP were detected in 5 kinds of tear tapes for cigarette packaging, and the contents were determined using the method. The phthalates was extracted with hexane by ultrasonically assisted procedure and ASE method respectively. The recoveries of the phthalates are between 70. 8% ~91. 7% with relative standard deviations of 7. 95% ~9. 82% when dealing with the ultrasonically assisted procedure, and between 82. 2% ~ 93. 8%% with relative standard deviations of 4. 95% ~ 7. 87% by the ASE procedure. It was concluded that the ASE procedure is the better pretreatment of tear tape for cigarette packaging.

Cite this article

Download Citations
LIU Dan, CHENG Juan, FANG Xi-ling, KUANG Shu-ting, WANG Zhi-wei. Determination of Phthalates in Tear Tapes for Cigarette Packaging Using Ultrasonic Extraction / ASE Method Coupling with GC-MS[J]. Packaging Engineering. 2013(19): 14-17

Accesses

Citation

Detail

Sections
Recommended

/