Determination of Hazardous Elements in Plastic Packaging Materials by Microwave Digestion with ICP-MS

QIU Jing, ZHENG Ping, HAN Fang, ZHANG Zhi, WANG Yong-xia

Packaging Engineering ›› 2011 ›› Issue (3) : 9-11.

Packaging Engineering ›› 2011 ›› Issue (3) : 9-11.

Determination of Hazardous Elements in Plastic Packaging Materials by Microwave Digestion with ICP-MS

  • QIU Jing1, ZHENG Ping2, HAN Fang2, ZHANG Zhi2, WANG Yong-xia2
Author information +
History +

Abstract

Plastic packaging materials were digested by mixed acids of nitric acid and hydrogen peroxide solution using high pressure and closed microwave digestion technology. A method for the determination of Pb, Cd, As, Cr, Sb, Hg, Se, Ba, Ni, Sn, Sr and Tl in packaging materials by ICP-MS was established. The detection limits are in the range of 0.02~0.20 μg/L; the relative standard deviations are less than 10%; the recoveries are in the range of 88.0%~117.0%. The results proved that this method is simple, accurate, and reliable.