同时测定药用玻璃中的砷和锑溶出量的方法研究

刘莉莉, 李克芳, 陈 方

包装工程(技术栏目) ›› 2012 ›› Issue (21) : 20-23.

包装工程(技术栏目) ›› 2012 ›› Issue (21) : 20-23.

同时测定药用玻璃中的砷和锑溶出量的方法研究

  • 刘莉莉1, 陈 方1, 李克芳2
作者信息 +

Study on Simultaneous Determination of Trace Release of Arsenic and Antimony from Pharmaceutical Glass Container

  • LIU Li-li1, CHEN Fang1, LI Ke-fang2
Author information +
文章历史 +

摘要

建立了氢化物发生原子荧光光谱法(HG-AFS)同时测定药用玻璃中的砷和锑溶出量的方法,并对 HG-AFS 工作参数及条件进行了优化和选择。 As 检出限为 0. 020 μg / L,Sb 检出限为 0. 024 μg / L;回收率范围为96% ~ 103% 。 本方法简便快捷、灵敏度高、专属性强、准确可靠,可作为药用玻璃容器的质量控制方法。关键词: 原子荧光; 药用玻璃; 砷和锑溶出量

Abstract

A new determination method of arsenic and antimony in pharmaceutical glass container using HG-AFS was established. Operation parameters of HG-AFS and condition were optimized and selected. The detection limit was As 0. 020 μg / L, Sb 0. 024 μg / L separately. The recovery was in the range of 96% ~ 103% . This method is proved to be simple, sensitive, specific and reliable, which can be used for quality control of pharmaceutical glass container.

引用本文

导出引用
刘莉莉, 李克芳, 陈 方. 同时测定药用玻璃中的砷和锑溶出量的方法研究[J]. 包装工程(技术栏目). 2012(21): 20-23
LIU Li-li, LI Ke-fang, CHEN Fang. Study on Simultaneous Determination of Trace Release of Arsenic and Antimony from Pharmaceutical Glass Container[J]. Packaging Engineering. 2012(21): 20-23