聚乙烯膜在65%乙醇浸泡液中蒸发残渣测量不确定度的评定

郭 风, 慕春玲, 郗 丹

包装工程(技术栏目) ›› 2012 ›› Issue (15) : 29-32.

包装工程(技术栏目) ›› 2012 ›› Issue (15) : 29-32.

聚乙烯膜在65%乙醇浸泡液中蒸发残渣测量不确定度的评定

  • 郭 风, 慕春玲, 郗 丹
作者信息 +

Uncertainty Evaluation of Evaporation Residue Measurement of Polyethylene Film in 65% Ethanol Soaking Liquid

  • GUO Feng, MU Chun-ling, XI Dan
Author information +
文章历史 +

摘要

采用市场上常见的液体包装用聚乙烯乳白单膜,实现了以65%乙醇为浸泡液,蒸发残渣测量不确定度的评定。通过实验与不确定度的影响因素分析,建立了蒸发残渣不确定度的数学模型,计算了各不确定度分量。实验结果表明:扩展不确定度为1.22 mg/L(k=2),蒸发残渣的测定结果为(7.0±1.22) mg/L。

Abstract

The uncertainty of evaporation residue determination was evaluated using polyethylene white film for packaging of liquids on the market and 65% alcohol as soaking solution. Influencing factors of uncertainty were analyzed by experimental methods. Mathematical model of uncertainty of evaporation residue was established and all sorts of uncertainty components were calculated. The experimental results showed that the expanded uncertainty was 1.22 mg/L(k=2) and the result of determination of evaporation residue was (7.0±1.22) mg/L.

引用本文

导出引用
郭 风, 慕春玲, 郗 丹. 聚乙烯膜在65%乙醇浸泡液中蒸发残渣测量不确定度的评定[J]. 包装工程(技术栏目). 2012(15): 29-32
GUO Feng, MU Chun-ling, XI Dan. Uncertainty Evaluation of Evaporation Residue Measurement of Polyethylene Film in 65% Ethanol Soaking Liquid[J]. Packaging Engineering. 2012(15): 29-32