微波消解-电感耦合等离子体质谱(ICP-MS) 同时测定塑料包装材料中有毒有害元素

邱 静, 郑 平, 韩 芳, 张 志, 王勇 霞

包装工程(技术栏目) ›› 2011 ›› Issue (3) : 9-11.

包装工程(技术栏目) ›› 2011 ›› Issue (3) : 9-11.

微波消解-电感耦合等离子体质谱(ICP-MS) 同时测定塑料包装材料中有毒有害元素

  • 邱 静1, 郑 平2, 韩 芳2, 张 志2, 王勇 霞2
作者信息 +

Determination of Hazardous Elements in Plastic Packaging Materials by Microwave Digestion with ICP-MS

  • QIU Jing1, ZHENG Ping2, HAN Fang2, ZHANG Zhi2, WANG Yong-xia2
Author information +
文章历史 +

摘要

采用硝酸-过氧化氢消解体系,及高压密闭微波技术处理塑料包装材料,建立了电感耦合等离子体质谱法同时测定塑料包装材料中铅、镉、砷、铬、锑、汞、硒、钡、镍、锡、锶、铊多种有毒有害元素的方法。 方法的检出限为0.0 2~0.2 0μ g / L,相对标准偏差(RS D)小于1 0%,加标回收率为8 8.0%~1 1 7.0%。 该方法简单、快速、灵敏、准确度好。

Abstract

Plastic packaging materials were digested by mixed acids of nitric acid and hydrogen peroxide solution using high pressure and closed microwave digestion technology. A method for the determination of Pb, Cd, As, Cr, Sb, Hg, Se, Ba, Ni, Sn, Sr and Tl in packaging materials by ICP-MS was established. The detection limits are in the range of 0.02~0.20 μg/L; the relative standard deviations are less than 10%; the recoveries are in the range of 88.0%~117.0%. The results proved that this method is simple, accurate, and reliable.

引用本文

导出引用
邱 静, 郑 平, 韩 芳, 张 志, 王勇 霞. 微波消解-电感耦合等离子体质谱(ICP-MS) 同时测定塑料包装材料中有毒有害元素[J]. 包装工程(技术栏目). 2011(3): 9-11
QIU Jing, ZHENG Ping, HAN Fang, ZHANG Zhi, WANG Yong-xia. Determination of Hazardous Elements in Plastic Packaging Materials by Microwave Digestion with ICP-MS[J]. Packaging Engineering. 2011(3): 9-11

基金

国家质检总局行业标准制 定项目(2010B009)

Accesses

Citation

Detail

段落导航
相关文章

/