药用橡胶塞中17种多环芳烃测定方法

张罗红, 黄婉莎, 张欣, 江燕

包装工程(技术栏目) ›› 2021 ›› Issue (17) : 10-19.

PDF(4700 KB)
PDF(4700 KB)
包装工程(技术栏目) ›› 2021 ›› Issue (17) : 10-19. DOI: 10.19554/j.cnki.1001-3563.2021.17.002

药用橡胶塞中17种多环芳烃测定方法

  • 张罗红, 黄婉莎, 张欣, 江燕
作者信息 +

Determination Methodology of 17 Polycyclic Aromatic Hydrocarbons in Pharmaceutical Rubber Stoppers

  • ZHANG Luo-hong, HUANG Wan-sha, ZHANG Xin, JIANG Yan
Author information +
文章历史 +

摘要

目的 建立药用橡胶塞中17种多环芳烃的气相色谱-串联质谱测定方法,评估其残留多环芳烃的安全性。方法 采用丙酮/正己烷(V丙酮∶V正己烷=1∶1)作为提取溶剂,微波萃取胶塞中目标物,以D8-萘、D10-芘、D12-苯并[a]芘为内标进行定量分析。结果 该方法在2~200 ng/mL线性良好,相关系数R为0.9984~0.9999,方法检出限范围为0.35~1.25 ng/g,回收率为92.24%~118.47%,测定结果的相对标准偏差为0.86%~13.23%。采用上述方法对市场上8个厂家的17批胶塞进行提取,其中均提取出不同多环芳烃,致癌性多环芳烃检出量为0.0004~0.1278 μg/g;3批胶塞检出苯并[α]芘量为0.0013~0.0042 μg/g;非明确致癌性多环芳烃检出量为0.0004~0.2980 μg/g。结论 该方法准确、灵敏、简便,可用于定量测定胶塞中残留的高风险致癌性多环芳烃(五环以上)。

Abstract

This paper developed determination methodology of gas chromatography-tandem mass spectrometry for 17 polycyclic aromatic hydrocarbons of pharmaceutical rubber stoppers to evaluate the safety of residual polycyclic aromatic hydrocarbons. A mixture of acetone-hexane (V丙酮∶V正己烷=1∶1) was used as the extraction solvent, the target substances of rubber stopper were extracted by microwave, and D8-naphthalene, D10-pyrene and D12-benzo[a]pyrene were used as internal standards for quantification analysis. Good linearity was observed within the range of 2-200 ng/mL, the correlation coefficient R was 0.9984-0.9999, and the limit of detection was in the range of 0.35-1.25 ng/g in this methodology. Besides, the recovery ranged from 92.24% to 118.47% (RSD:0.86%-13.23%). The above method was used to extract 17 batches of rubber stoppers from 8 manufacturers on the market, and different polycyclic aromatic hydrocarbons were extracted from them. The detected amount of carcinogenic PAHs was in the range of 0.0004 to 0.1278 μg/g, benzo[α]pyrene from 3 batches of the rubber stoppers were in the range of 0.0013-0.0042 μg/g and the detected amount of unclear carcinogenic PAHs was 0.0004-0.2980 μg/g. This method is accurate, sensitive, simple and suitable for the quantitative determination of the residual high-risk carcinogenic polycyclic aromatic hydrocarbons (above five rings) in rubber stoppers.

引用本文

导出引用
张罗红, 黄婉莎, 张欣, 江燕. 药用橡胶塞中17种多环芳烃测定方法[J]. 包装工程(技术栏目). 2021(17): 10-19 https://doi.org/10.19554/j.cnki.1001-3563.2021.17.002